Add to Cart
Features
| Low profile, parallel beam construction | test certificate no. TC8407 Revision 0 |
| Anodized aluminum alloy | C of C no. R60/2000-NL1-13.22 Revision 1 |
Available models
Capacity | Accuracy | Full article description |
22kg | C3 | L6P-C3-22kg-1.5P |
45kg | C3 | L6P-C3-45kg-1.5P |
75kg | C3 | L6P-C3-75kg-1.5P |
110kg | C3 | L6P-C3-110kg-1.5 P |
Detailed specifications L6P
Accuracy class | OIML R60 C3 | |
Output sensitivity ( = FS ) | mV/V | 1.0 ± 0.1 |
Maximum capacity ( Emax ) | kg | 22, 45, 75, 110 |
Max.number of load cell intervals | nLC | 3000 |
Ratio of min. LC verification interval | Y = Emax / vmin | 10000 |
Combined Error | %FS | ≤± 0.0230 |
Minimum dead load | Of Emax | 0% |
Safe overload | of Emax | 150 % |
Ultimate overload | of Emax | 300 % |
Zero balance | of FS | < ± 1.0 % |
Excitation, recommended voltage | V | 5 ~ 12 |
Excitation maximum | V | 18 |
Input resistance | Ω | 1065 ± 15 |
Output resistance | Ω | 1000 ± 10 |
Insulation resistance | MΩ | ≥5000 ( at 50VDC ) |
Compensated temperature | °C | -10 ~+40 |
Operating temperature | °C | -35 ~ +70 |
Storage temperature | °C | -35 ~ +80 |
Element material | Aluminium | |
Ingress Protection (acc. to EN 60529) | IP65 | |
Recommended torque on fixation | Nm | M4: 3 |
Wiring
Wiring:
4 conductor flat ribbon cable. Cable diameter: Ø1.2mm.